| Forced Ventilation Units for speed controlled electric motors |
![]() |
Since more than 25 years we produce forced
ventilation units for the electric motor manufacturers.Our
experiences are your guarantor for quality and flexible
solutions. Electric motors with forced ventilation units are used in all fields of the industry. From the food processing industry up to rolling mills and offshore applications – they all have different demands on the motors and forced ventilation units. |
Different forced ventilation units are available for any special field of application. We offer standardized forced ventilation units in IP 66 but also customized solutions. All forced ventilation units are specially manufactured according to customer´s demand to fit on each individual electric motor / gear. Thus, a simple mounting or change of the units is assured.
The existing fan cowl of the electric motor will be exchanged against the complete forced ventilation unit, while the standard ventilation fan will be disassembled.Our units are equipped with a separate terminal box and are delivered primed. (also without terminal box available)
|
|
The forced ventilation units FBI are designed for the cooling of electric motors driven by a frequency inverter in duty S1 up to S9.
These forced ventilation units are used for example in plant construction and mechanical engineering, in the field of hoisting and winding etc.
Moreover available forced ventilation units in insul. class H, special voltages, tropical protection, dust-protection bearings and space heaters (frame 112 - 400).
We would be pleased to receive your detailed enquiry for our standard as well as customized components.
Please use our reply telefax for your enquiry or contact us directly by phone.
| Overview - Forced Ventilation Units |
By clicking on thr respective illustation you will get to the cooesponding downloads.
| Forced Ventilation Units Type AH datasheet Mb 0E |
Forced Ventilation Units in IP 66 with special ventilation fan to ensure a low run at a simultaneously higher output. These units can be operated at a higher ambient temperature of max. 70 °C.
The forced ventilation units are according to UL/CSA.
Interchangeable adapters can be made according to customer´s requirements.
| Download |
You will require "Adobe Reader" to read the PDF-files
![]() Delivery conditions |
![]() FBI Info (AH) |
![]() Instruction |
![]() Connection table AH |
![]() Enquiry datasheet |
FBI motor-unity Forced ventilation motor-unity plus extension as complete forced ventilation unit
![]() AH (UL/CSA) |
![]() Rain cover for type AH |
Extensions (adapter) in connection with the motor-unity as complete forced ventilation unit
Extensions (adapters) for all types of motors as well as special dimensions available at batch sizes of 1 piece.
![]() kMMp (Standard) |
||||
![]() Bonfiglioli |
||||
![]() Dutchi |
||||
![]() Elektrim |
||||
![]() SEW |
![]() Siemens ie |
|||
![]() VEM |
Should you require data sheets of other motor manufacturers or spezial dimensions please contact us.
| Forced Ventilation Units Type RBK datasheet Mb 1E |
Identity dimensions as RBK Mb 1K but with UL / CSA approved motor. Complemental to Mb 0E for the frame sizes 200 - 400.
| Download |
You will require "Adobe Reader" to read the PDF-files
![]() Delivery conditions |
![]() Instruction |
![]() Connection table RBK |
![]() Enquiry datasheet |
FBI motor-unity Forced ventilation motor-unity plus extension as complete forced ventilation unit
![]() RBK (UL/CSA) |
Extensions (adapter) in connection with the motor-unity as complete forced ventilation unit
Extensions (adapters) for all types of motors as well as special dimensions available at batch sizes of 1 piece.
![]() kMMp (Standard) |
||||
![]() ABB |
||||
![]() Dutchi |
||||
![]() Marelli |
||||
![]() Siemens |
||||
![]() VEM |
||||
![]() WEG |
Should you require data sheets of other motor manufacturers or special dimensions please contact us.
| Forced Ventilation Units Type RBK datasheet Mb 0K / 1K |
This forced ventilation series offers a wide voltage range of 230 to
333 Volt respectively 400 to 575 Volt three-phase in IP 66.
The boltabel and
changeable extensions (connecting adapter) can be modified and
adapted to the required motor connecting
The very high stiffness and stability in connection with our
flexible assembly possibilities for the extensions and the wide
electric field of application offers you a
cost-effective, technically high-quality solution for your
motors.
We supply forced ventilations in special versions – for example insul. Class H, with thermistors, special paint, tropical protection, rain cover etc.
| Download |
You will require "Adobe Reader" to read the PDF-files
![]() Delivery conditions |
![]() FBI Info (RBK) |
![]() Instruction |
![]() Connection table RBK |
![]() Enquiry datasheet |
FBI motor-unity Forced ventilation motor-unity plus extension as complete forced ventilation unit
![]() RBK |
Extensions (adapter) in connection with the motor-unity as complete forced ventilation unit
![]() kMMp (Standard) |
||||
![]() ABB |
![]() AEG |
![]() ATB |
||
![]() Bauer |
![]() Bonfiglioli |
|||
![]() Dutchi |
||||
![]() Flender |
||||
![]() SEW |
![]() Siemens |
|||
![]() VEM |
||||
![]() WEG |
Should you require data sheets of other motor manufacturers or special dimensions please contact us.
| Contact |
| For further information please contact us . . . |
|